Programmable relay, to turn off non critical loads or to run a generator when needed.Remaining time at the current rate of discharge.Battery voltage, current, power, ampere-hours consumed and state of charge.Prevents increased current draw in case of an alarm.

A residual current of 10mA for example may damage a 200Ah battery if the system is left in discharged state during more than 8 days.

The battery will be damaged if the remaining capacity reserve is drawn from the battery. After shutdown due to low cell voltage, the capacity reserve of a Li-ion battery is approximately 1Ah per 100Ah battery capacity. Please see the BMV manual, section 5.2, for more information.Ĭurrent consumption: 0,7Ah per month (1mA) and 0,6Ah per month (0,8mA) 24V Especially Li-ion batteries have virtually no capacity left when discharged until low voltage shutdown. When batteries are connected in series, a timely warning can be generated by measuring the midpoint voltage. One bad cell or one bad battery can destroy a large, expensive battery bank.
VICTRON LITHIUM BATTERY MONITOR HOW TO
Video: how to connect BMV battery monitors Included: RJ 12 cable (10 m) and battery cable with fuse (2 m) no other components needed.Īlso included are a separate front bezel for a square or round display appearance, a securing ring for rear mounting and screws for front mounting. The shunt connects to the monitor with a standard RJ12 telephone cable.